UNS C11000 Wire
In general, copper alloys exhibit good to excellent corrosion resistance and high thermal conductivity and very high electrical conductivity.
CALL US:
1-866-725-8609In general, copper alloys exhibit good to excellent corrosion resistance and high thermal conductivity and very high electrical conductivity.
Electrical/electronic and solar applications where strength is not required. Additional applications are downspouts, gutters, roofing, gaskets, heat sinks, busbars, nails, printing rolls, rivets, etc. parts.
In general, copper alloys exhibit good to excellent corrosion resistance and high thermal conductivity and very high electrical conductivity. Pure copper's electrical conductivity is so high that many metals are measured against it in the form of the IACS (International Annealed Copper Standard).
C10100 99.99 min 0.0005 max 0.0005 max
C10200 99.95 min 0.0001 max 0.0003 max
C10400 99.95 min 0.0001 max 0.027 min
C10500 99.95 min 0.0001 max 0.034 min
C10700 99.95 min 0.0001 max 0.085 min
C11000 99.90 min
C12000 99.90 min 0.004-0.012
C12100 99.90 min 0.014 0.004-0.012
C15000 Balance* 0.10-0.20 Zr
C15500 99.75 min 0.027-0.10 0.400-0.080 0.08-0.13 Mg
* Contact Ulbrich Wire for request regarding the availability of other copper alloys.
* Contact Ulbrich Technical Department for limits for additional trace elements and impurity levels.
* Copper Values include Silver.
* Copper plus named elements.
Typical Density: 0.332 lbs/in3, 8.92 g/cm3
Electrical Conductivity:(% IACS at 68° F 20°C, annealed): 85-101%
Specific Heat: BTU/lb-° F (J/g-°C): 0.0920 (0.385)
Mean Coefficient of Thermal Expansion: µin/in-° F (µm/m-°C)
68 - 572 °F (20 - 300 °C): 9.8 (17.6)
Thermal Conductivity: BTU-in/hr-ft2-° F (W/m•K): 2712 (390.8)
Modulus of Elasticity: KSI (MPa)
17 x 103 in tension
Melting Range: 1981 °F (1083 °C)
Profile, Round, Flat, Square
Ultimate Tensile Strength: 26 - 38 KSI (179 - 262 MPa)
Yield Strength: 10 KSI (69 MPa) Nominal
Elongation: 35%
Copper alloys can be cold worked to various tempers.
*Actual physical and mechanical properties are alloy dependent. Contact Ulbrich Technical Service for alloy specific properties.
Contact Ulbrich Wire for specific information.
XC - Extra clean. Annealed or annealed and cold rolled. Contact Ulbrich Wire with special finish requests.
Copper alloys are non hardenable by heat treatment.
Contact Ulbrich Wire for specific information.
Limitation of Liability and Disclaimer of Warranty: In no event will Ulbrich Stainless Steels & Special Metals, Inc., be liable for any damages arising from the use of the information included in this document or that it is suitable for the 'applications' noted. We believe the information and data provided to be accurate to the best of our knowledge but, all data is considered typical values only. It is intended for reference and general information and not recommended for specification, design or engineering purposes. Ulbrich assumes no implied or express warranty in regard to the creation or accuracy of the data provided in this document.
Thanks for your interest in Ulbrich! Whether you're developing a new product or ramping up production, we'll be happy to learn more about your specific needs. Please fill out the form below, and we will promptly get back to you with a quote or, if needed, a request for more information.